Background
It is always possible that you may have some issues while configuring a X45e unit till it runs as required. This guide should help to fix the most usual issues when starting to use X45e units.
Prerequisites
Hardware
- PC (Windows 7 or later)
- X45e units (with power cables)
- Parameter Setting Tool cable (X45e) or mini USB cable depending on hardware version
Software
- X45e – Parameter Setting Tool (PST)
First step
First thing to do with a new X45e unit should always be to update the firmware. Usually a delivered X45e unit will not have latest firmware version. Current firmware version at X45e unit can be seen at Monitor page of PST. Latest firmware version is available at FlexLink hompage -> Download engineering tools -> Intelligent Conveyor Software (X45e).
Connection to PST
PST has to be installed and running. X45e unit has to be powered so that LED light up. Connection type is selectable in PST menu Network / X45e.
CAN-bus
Issue | Reason | Solution |
---|---|---|
No connection device found. |
Kvaser Leaf Light not connected at computer. |
Connect Kvaser Leaf Light to computer. |
Kvaser driver not installed. |
Install driver from PST installation folder \ resources. |
|
No X45e device found during network scan. |
Kvaser Leaf Light not connected to correct connector (A-bus, B-bus) at X45e unit. |
Connect Kvaser Leaf Light to correct connector (A-bus, B-bus) at X45e unit. |
Kvaser Leaf Light connected to A-bus but A-bus is not powered. |
Use B-bus instead or power the A-bus as described in "User documentation – Electrical System (X45e)". |
|
Kvaser Leaf Light connected to A-bus but wrong protocol (CANopen, DeviceNet) selected. |
Use B-bus to check and maybe change A-bus protocol. |
USB
Issue | Reason | Solution |
---|---|---|
No connection device found. |
USB cable not connected to computer or X45e unit. |
Connect USB cable to computer and X45e unit. |
USB cable is only made for power (2 pins) not for data transfer (4 pins). |
Replace USB cable by a cable that is definitely made for data transfer. |
|
No or wrong driver installed. |
A new COM port should appear in Device-Manager when connecting X45e unit via USB. Correct driver is located in PST installation folder \ docs. |
Ethernet/IP
Issue | Reason | Solution |
---|---|---|
No X45e device found during network scan. |
Computer and X45e unit are not in same network. |
Make sure that network cables are connected and computer is using same network as X45e unit. |
X45e unit is not configured for Ethernet/IP communication. |
Connect X45e unit via USB and configure it for Ethernet/IP communication. |
|
Firewall is blocking required ports. |
Following ports must not be blocked: 2222/UDP, 44817/UDP, 44818/TCP, 3000/TCP |
|
Error during network scan. IOException: java.util.concurrent.ExecutionException: io.netty.handler.codec.DecoderException: unhandled item type: 0x86 |
An Ethernet/IP device in same network supports security. |
Update PST to latest version. This is handled since version 3.5.8 |
ProfiNet
Issue | Reason | Solution |
---|---|---|
No X45e device found during network scan. |
Computer and X45e unit are not in same network. |
Make sure that network cables are connected and computer is using same network as X45e unit. |
X45e unit is not configured for ProfiNet communication. |
Connect X45e unit via USB and configure it for ProfiNet communication. |
|
Firewall is blocking required ports. |
Following ports must not be blocked: 34964/UDP, 49152/UDP, 3000/TCP |
|
WinPcap library not installed. |
Install Wireshark or WinPcap from PST installation folder \ resources. |